12 Karazana otrikaretina taovam-pisefoana
Anaran'ny vokatra
HWTS-RT071A 12 karazana fitaovam-pitaterana asidra nucleic pathogen (Fluorescence PCR)
fantsona
fantsona | hu12Reaction Buffer A | hu12Reaction Buffer B | hu12Reaction Buffer C | hu12Reaction Buffer D |
FAM | SARS-CoV-2 | HADV | HPIV Ⅰ | HRV |
VIC/HEX | Fanaraha-maso anatiny | Fanaraha-maso anatiny | HPIV Ⅱ | Fanaraha-maso anatiny |
CY5 | IFV A | MP | HPIV Ⅲ | / |
ROX | IFV B | DIEM | HPIV Ⅳ | HMPV |
Paramètre ara-teknika
fitahirizana | ≤-18 ℃ |
talantalana-fiainana | 12 volana |
Karazana karazana | Oropharyngeal swab |
Ct | ≤38 |
CV | ≤5.0% |
Loda | SARS-CoV-2: 300 Kopia/mLotrikaretina gripa B: 500 Kopia/mLotrik'aretina gripa A: 500 Kopia/mL Adenovirus: 500 Kopia/mL mycoplasma pneumoniae: 500 Kopia/mL virus syncytial respiratory: 500 Copies/mL, virosy parainfluenza (Ⅰ, Ⅱ, Ⅲ, Ⅳ): 500 Kopia/mL Rhinovirus: 500 Kopia/mL metapneumovirus olombelona: 500 Copies/mL |
manokana | Ny fandalinana cross-reactivity dia mampiseho fa tsy misy fifampiraharahana eo amin'ity kitapo ity sy ny enterovirus A, B, C, D, virus epstein-barr, viriosy kitrotro, cytomegalovirus olombelona, rotavirus, norovirus, virus mumps, viriosy varicella-herpes zoster, bordetella pertussis, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans ary asidra nokleika genomika olombelona. |
Fitaovana azo ampiharina | Applied Biosystems 7500 Real-Time PCR SystemsApplied Biosystems 7500 Fast Real-Time PCR SystemsQuantStudio®5 Rafitra PCR amin'ny fotoana tena izy SLAN-96P Real-Time PCR Systems(Hongshi Medical Technology Co., Ltd.) LightCycler®480 rafitra PCR Real-Time, LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer teknolojia) MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Rafitra PCR Real Time |
Fizotran'asa
Safidy 1.
Reagent fitrandrahana atolotra: Reagent famotsorana santionany Macro & Micro-Test (HWTS-3005-8) nataon'i Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Ny fitrandrahana dia tokony ho tanterahina araka ny toromarika.
Safidy 2.
Reagent fitrandrahana atolotra: Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) ary Macro & Micro-Test Automatic Nucleic Acid Extractor ( HWTS-3006C, HWTS-3006B) nataon'i Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., ny fitrandrahana dia tokony hatao araka ny toromarika hentitra.Ny habetsahan'ny elution atolotra dia 80μL.
Safidy 3.
Reagent fitrandrahana soso-kevitra: Ny fitrandrahana asidra nucleic na Kit fanadiovana (YDP315) avy amin'ny Tiangen Biotech (Beijing) Co., Ltd., ny fitrandrahana dia tokony hatao araka ny torolàlana hentitra.Ny habetsahan'ny elution atolotra dia 100μL.